What commercial roofing actually involves

Commercial roofing is not the same as domestic work. The buildings are larger, the roof areas are often flat or low-pitch, the materials are industrial-grade, and the consequences of getting it wrong fall on a business rather than a household. A leaking warehouse roof can damage stock. A failed office roof can shut down a workspace. Getting the job done properly, in the right sequence, matters more than it might on a house.

On this page we walk you through the full process, from the first look at a roof through to packing up and leaving the site clean. If you are deciding whether to repair or replace, or trying to understand what a contractor should actually be doing at each stage, this is the information you need.

Step one: the initial roof survey

Every commercial roofing job starts with a proper survey. That means getting eyes on the whole roof, not just the area directly above a reported leak. On large flat roofs, water can travel a considerable distance from where it enters to where it shows on a ceiling, so the visible damage and the actual problem are often in different places.

A thorough survey should assess the existing membrane, sheeting or felt layers; the condition of any upstands, flashings and edge trims; the drainage outlets and guttering; and the substrate or decking beneath. On older buildings the decking itself can be soft, delaminated or rotten, and that affects the specification for any replacement. It is worth asking your contractor to give you a written summary of what the survey found, not just a price.

For profiled metal roofs on farm units and industrial buildings, the survey should also check the condition of fixings and laps, the state of any translucent roof lights, and whether the existing purlins are sound. Corroded or loose fixings are a common cause of water ingress on metal-clad roofs and are easily missed if the survey is rushed.

Step two: specifying the right system

Once the survey is complete, the right material needs to be chosen for the building and its use. There is no single answer that suits every commercial building, and a contractor who quotes the same system for everything should be questioned.

For flat or shallow-pitch roofs, the two systems used most on commercial buildings are single-ply membrane and built-up felt. Single-ply membranes, including EPDM rubber, are welded or adhered to the deck and form a continuous waterproof layer with very few joints. They perform well on large roof areas and are lighter than multi-layer felt systems. EPDM in particular is known for remaining flexible in cold weather and resisting UV degradation over many years.

Built-up felt systems use multiple layers of bitumen-based felt, torched or cold-applied, to build up a waterproof barrier. They are a proven option on commercial buildings and a well-installed system on a sound deck gives reliable long-term performance. Typical installed costs for commercial flat roofing run from around £70 to £120 per square metre depending on the system, the deck condition and access requirements. Large roof areas generally bring the unit cost down.

For pitched roofs on commercial premises, profiled metal sheeting is the standard choice for agricultural and industrial buildings. It is fast to install, durable and available in a range of profiles and colours. Fibre-cement and concrete tiles are used on retail and office buildings where appearance matters more. Slate, either natural or fibre-cement, is occasionally specified on older or listed commercial premises.

  • Single-ply membrane (EPDM): suited to large flat or low-pitch areas, lightweight, long-lasting, minimal joints
  • Built-up felt: multi-layer system, reliable on sound decking, suitable for most commercial flat roofs
  • Profiled metal sheeting: standard for farm buildings, warehouses and industrial units, quick to install
  • Pitched tiles or slate: used on retail and office buildings, or where planning requires a traditional appearance

Step three: preparation and stripping

On a replacement job, the old roofing material has to come off before the new system goes on. On flat roofs this means stripping back the existing felt or membrane layers to expose the decking. What the deck looks like underneath is often not fully known until this point, and it is normal for a contract to include provisional allowances for deck repairs that are confirmed once the strip-out is complete.

Timber decking on older flat roofs is frequently found to be soft in patches, particularly around outlets and at edges where water has sat. Rotten boards need to be cut out and replaced with matching thickness material before anything goes on top. Skipping this step and roofing over soft decking is the single most common reason commercial flat roofs fail prematurely.

On metal-clad buildings a full strip is not always necessary. If the existing sheeting is sound and the purlins are in good condition, it is sometimes possible to over-clad using a standing-seam or secret-fix system. This avoids the cost and disruption of a full strip and keeps the building weathertight throughout the process. Whether over-cladding is the right call depends on the survey findings.

Waste from a commercial strip-out is significant. Old bitumen felt, metal sheeting and insulation boards all need to be removed from site and disposed of correctly. The work area should be kept clear and any access equipment, including scaffolding or MEWP, positioned so that business operations on the ground are disrupted as little as possible.

Step four: installing the new roof

Installation method depends on the system specified. For a single-ply EPDM membrane on a flat roof, the sequence is typically: fix any required insulation boards to the deck, then adhere or mechanically fix the membrane in sheets, weld all joints with a hot-air tool, and detail all upstands, outlets and edges with bonded trims and flashing strips. Every junction is a potential weak point, so detailing takes time and should not be rushed.

For built-up felt, the base layer goes down first, followed by intermediate and cap sheet layers, each torched or cold-bonded to the layer below. The cap sheet is usually a mineral-surfaced finish that reflects heat and provides UV protection. Outlets should be dressed carefully so the felt laps into them rather than sitting proud, which can hold water.

On pitched roofs, metal sheeting is fixed to purlins in overlapping sheets with sealed laps and purpose-made ridge, eaves and barge flashings. Fixings go through the crown of the profile, not the trough, to prevent water pooling around the screw head. Roof lights, if required, are fitted in matching profiles with proper weathering at the top and bottom lap.

Insulation is increasingly specified on commercial roofs, both for thermal performance and condensation control. On flat roofs it sits between the deck and the membrane (warm roof construction) or below the deck (cold roof). Warm roof construction is generally preferred because it keeps the deck at a higher temperature and reduces the risk of condensation within the build-up.

Step five: flashings, outlets and edge details

The waterproof membrane or sheeting itself is only part of the job. Flashings at parapets, rooflights, pipework penetrations, abutments with walls and at changes of level are where the majority of commercial roof failures occur. These details are labour-intensive and require care, but they are what separates a roof that lasts from one that leaks within a few years.

Lead is still the standard material for complex flashings on pitched roofs and at abutments. On flat membrane roofs, pre-formed EPDM or aluminium trims are used at edges, with the membrane bonded into them. Outlets on flat roofs should be raised slightly on collars so that any minor ponding does not sit against the membrane edge.

Guttering and downpipes on commercial buildings carry large volumes of water and need to be sized accordingly. Undersized guttering is a common problem on older farm and industrial buildings, particularly if the roof area has been extended at some point. It is worth checking that the drainage specification matches the actual roof area being drained.

Common faults found on commercial roofs

Blistering on flat felt roofs is caused by moisture trapped in the felt layers during installation or by poor adhesion between layers. Once a blister forms it weakens the surface and, if it splits, lets water in. Small blisters can sometimes be cut, dried and re-bonded; larger areas usually need to be stripped and relaid.

Lap failures on profiled metal roofs happen when sealant in the laps dries out and cracks, or when fixings loosen and allow the sheets to move. Water then wicks up through the lap by capillary action, which is why metal roof manufacturers specify a minimum pitch for each profile. If a metal roof was put on at too shallow a pitch, lap failures are almost inevitable over time.

Blocked outlets are behind a surprising number of flat roof leaks. Water backing up behind a blocked outlet saturates the upstand details and eventually finds a way through. Keeping outlets clear is straightforward maintenance but it is often neglected on commercial buildings. A simple annual check in autumn, before leaf fall blocks things up, prevents a lot of damage.

Cracked or displaced flashings are the most common source of water ingress on pitched commercial roofs. Mortar-bedded flashings expand and contract with temperature changes and eventually crack. Step and soaker flashings on slate or tile roofs can slip if the mortar perishes. Lead flashings last well when correctly dressed but can pull away from chases in brickwork if the lead clip fixings fail.

Repair or replace? How to decide

This is the most important question on any commercial roofing job and the answer depends on the survey findings rather than the age of the roof alone. A 30-year-old felt roof that has been maintained, has sound decking and only localised damage may be repairable for several more years. A 15-year-old roof that was poorly installed on damp decking may need full replacement.

As a general guide, if repairs would cost more than 40-50% of the cost of replacement, a new roof usually makes better financial sense. Patching a failing roof repeatedly costs more in the long run and does not stop the underlying deterioration. If the decking is compromised, repair is rarely the right answer because the new surface will only fail again.

For any commercial building, the survey findings should drive the decision. There is no shortcut to getting a proper look at what is there before committing to a course of action.

Typical commercial roofing costs

Commercial flat roof replacement typically runs from around £70 to £120 per square metre for felt or EPDM systems, installed, depending on deck condition and access. Profiled steel cladding on agricultural or industrial buildings costs roughly £25 to £55 per square metre for re-roofing in a standard box profile, with over-cladding at the lower end of that range. These figures exclude any structural repairs, specialist access or unusually complex detailing.

Roof repairs on commercial buildings are usually priced per job rather than per square metre. A single failed flashing or a localised membrane repair might cost a few hundred pounds; a programme of works addressing multiple problems across a large roof will naturally cost more. Ask for a schedule of the work to be done and the materials to be used, so you can compare quotes on a like-for-like basis.

Scaffolding and access equipment can add significantly to the overall cost on taller buildings. A mobile elevated work platform is often cheaper than scaffolding on single-storey industrial roofs where the perimeter is accessible. On multi-storey premises or where work is needed near a public footway, full scaffolding is usually required for safety reasons.

Step six: inspection and clean-up

Before any commercial roofing job is signed off, the completed roof should be walked and inspected. Every outlet should be checked to make sure it is clear and properly dressed. Every flashing and upstand detail should be checked for adhesion and correct overlap. On membrane roofs, any welded seams can be tested by running a probe along them to check they are fully fused.

Any off-cuts, waste felt, old fixings and packaging should be cleared from the roof surface and from the ground around the building. Leaving debris on a flat roof is not just untidy, it blocks outlets and can puncture membranes as it is walked on in future. The site should be left in a condition where the building can go straight back into normal use.

After completion, it is sensible to keep a note of the system installed, the materials used and the date of the work. This information is useful if you ever need to arrange an inspection or match materials for a later repair. Ask your contractor to confirm in writing what was installed.

Get a survey and quote for your commercial roof

If you have a commercial or industrial roof in Southery or nearby, call Downham Market Roofers to arrange a roof survey. We will assess the full roof, tell you honestly what we find, and set out your options clearly before any work begins.

Why choose Downham Market Roofers?

  • Free survey and itemised quote
  • Fixed price - no surprises
  • Local team

Get your free quote

No obligation · We'll call you to arrange a free visit

By submitting you agree to being contacted about your enquiry. No spam, ever.

Urgent leak or storm damage?

Call any time. Calls are answered day and night and passed straight to our roofers.

Call now: 01366 312325